Calculation of Energy Available from Flue Gases
Specific heat of exhaust gases / m3 for 800-9000C = 0.308 kcal/m3/c0
Temperature of exhaust gas available from the existing Rotary kiln - 8500C
Temperature of exhaust gas after vertical drier - 2500C
-------------
Usable heat - 6000C
Hence, heat available = 0.308 X 6000C
= 184.8 kcal.
Quantity of heat available per hour = 24,000 m3/hour
Total heat available = 184.8 X 24,000 = 4,435,200 kcal / hour
Capacity of Vertical drier = 20 tons per hour
Water evaporation per hour = 1,600 kgs (based on 8% moisture)
Energy needed per kg of water evaporation - 625 kcal
Total heat spent on water evaporation - 10,00,000 kcal/hour
Remaining heat available for pre-heating – 3,435,200 kcal/hour